power entry modules with line filter felcom 54 www.schurter.com/pg0 6 emc products iec appliance inlet c14 modular assembling options 5411.xx5x.xxx appliance inlet fuseholder line filter 5431.x05x.xxx appliance inlet appliance outlet switch line filter standard- or medical-filter c14 70 c f 70 c description - panel mount: snap-in version from front side - 2 - 5 functions: appliance inlet protection class i, connector, line switch 2-pole, fuse - holder for fuse-links 5 x 20 mm 1- or 2-pole, line filter in standard and medical version - solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm approvals - vde certificate number: 101307 - ul file number: e72928 characteristics - modular component selection - individual components soldered on a printed circuit board - plug removal necessary for fuse-link replacement fuse drawer meets requirements of medical standard iec/en 60601-1 the fuseholder is accessible from the equipment front - technical data of filter-components see blockfilter type 5500 - fully insulated from the rear - qualified for use in equipment according iec/en 60950 other versions on request - line switch with other rocker marking references alternative: version without line filter felcom 6 4 weblinks pd f , general product informatio n , approval s , roh s , china-roh s , mating connector s , e-stor e , schurter-stock-chec k , distributor- stock-chec k , accessorie s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 250 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm panel thickness s snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5 /2/2.5/3 mm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, f acc. to iec/en 60320-2-2, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 2 w (1 pole)/ 1.6 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch rocker switch 2-pole, non-illuminated, acc. to iec 61058-1 technical detail s line filter standard version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'400'000 h acc. to mil-hb-217 f
power entry modules with line filter felcom 54 www.schurter.com/pg0 6 emc products dimensions variants 5411.xx5x.xxx mounting ?: 63+0,2 x 27.6+0,2 variants 5421.x05x.xxx mounting ?: 85.9+0,2 x 27.6+0,2 variants 5423.xx5x.xxx mounting ?: 96.4+0,2 x 27.6+0,2 variants 5424.xx5x.xxx mounting ?: 87.9+0,2 x 27.6+0,2 variants 5431.x05x.xxx mounting ?: 111.1+0,2 x 27.6+0,2 variants 5432.xx5x.xxx mounting ?: 121.6+0,2 x 27.6+0,2 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 8 standard version 2 x 0.6 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 8 medical version (m5) 2 x 0.6 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1
power entry modules with line filter felcom 54 www.schurter.com/pg0 6 emc products diagrams 5411 1) line 2) load 1 5421 1) load 2 2) load 1 5423 1) load 2 2) load 1 5424 1) line 2) load 1 5431 1) load 2 2) load 1 5432 1) load 2 2) load 1 derating curves 1-pole admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c 2-pole admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.6 0.6 0.4 0.8 1.2 1.0 1.4 ambient air temperature ta c or dering instructions 54 xx . x x xx . x x x base model ty pe of line filter 1 = standar d 3 = m edical ?snap-in? panel thicknes s 10 = 1,0 mm 12 = 1,2 mm 15 = 1,5 mm 20 = 2,0 mm 25 = 2,5 mm 30 = 3,0 mm connection 51 = s older terminals 3,5 x 0,8 mm 53 = q uick connect terminals 6,3 x 0,8 mm fuseholder 5 x 20 mm 0 = w ithout fuseholde r 1 = 1 -pole 2 = 2 -pol e line filte r 1 = 1 amp . 2 = 2 amp . 4 = 4 amp . 6 = 6 amp . 8 = 8 amp . 9 = 1 0 amp . module combinatio n 11 = a ppliance inlet, fuseholde r 21 = a ppliance inlet, appliance outle t 23 = a ppliance inlet, fuseholde r, appliance outlet 24 = a ppliance inlet, fuseholde r, switch 31 = a ppliance inlet, appliance outlet, switc h 32 = a ppliance inlet, fuseholde r, appliance outlet, switch packaging unit 0 pcs technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 8 standard version 2 x 0.6 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 8 medical version (m5) 2 x 0.6 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1
4 power entry modules with line filter felcom 54 www.schurter.com/pg0 6 emc products accessorie s description cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating inlets/plug s category / description interconnection cordoverview complet e interconnection cord with iec plug e, angled 060 7 interconnection cord with iec plug e, angled 060 8 interconnection cord with iec plug e, straight 060 9 interconnection cord with iec plug g, angled 607 b interconnection cord with iec plug g, angled 608 b interconnection cordfurther types tofelcom 5 4 ... plugoverview complet e iec plug e, cord connector (rewireable), straight, max. cable diameter 8.5 mm 473 2 iec plug e, cord connector (rewireable), angled, max. cable diameter 10 mm 473 3 iec plug e, cord connector (rewireable), straight, max. cable diameter 10 mm 473 5 iec plug e, cord connector (rewireable), angled, max. cable diameter 10 mm 473 6 iec plug e, cord connector (rewireable), straight 900 9 plugfurther types tofelcom 5 4 ... mating outlets/connector s appliance outletoverview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outletfurther types tofelcom 5 4 connectoroverview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connectorfurther types tofelcom 5 4 ... power cordoverview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cordfurther types tofelcom 5 4 ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.
|